I10 KV

I10 KV

Features

  • Up to 10 aluminium foil blisters in a package
  • Programmable for 255 different package sizes
  • Maximum package height 100 mm
  • Minimum blister size 30 x 60 mm in the transportation direction
  • Calibration with a teach-in procedure

Technical data

Applications:                                      Fast detection of incorrect package filling conditions in the cartoner with up to 10 blisters
Material thickness: Aluminium/PVC foil blister as well as alu/alu blisters
Measuring method: Inductive eddy current principle
Functional principle: The sealed package travels through an alternating magnetic field. The generated eddy currents are indicative of the correct or incorrect number of blisters strips in the package.
Programs: 255
Switching threshold: Underfill and overfill conditions
Special features: Due to the variations in the design of transportation belts custom sensor arrangements are available.