I20
| Modular Units R1000 |
- Non contact dual sensor Double Sheet Detector of steel and non-ferrous materials
- 3 interchangeable pairs of sensors for Double Sheet Detection:
steel .005 - 8.00 mm (.0001 - .315 in.) and non-ferrous materials .01 up to 16.00 mm (.0004 - .629 in.) according to material type
- Adjustment by Teach-In procedure
- Digital indication of sheet thickness and operational parameters
- Memory for 255 different parameter sets (sheet thicknesses)
- Monitoring of over gauge and under gauge limits
- Monitoring of supply voltage and sensor gap
- Data backup via USB interface (also via Fieldbus)
- Inputs of Fieldbus version:
Addressing via Fieldbus
Measurement start also via potential free 3-bit PLC input interface - Inputs of I/O version: Addressing via potential free 10-bit PLC input interface
- Potential free outputs for under gauge, nominal gauge, over gauge, warning and enable Opto coupler
- Optional Fieldbus interfaces: Profibus, DeviceNet, ControlNet, Interbus, CANopen, ProfiNet
- I20-2-O-S: 2-channel system with Optocoupler-IO interface
- I20-4-O-S: 4-channel system with Optocoupler-IO interface
- I20-2-xx-S: 2-channel system with Optocoupler-IO and Fieldbus interface
- I20-4-xx-S: 4-channel system with Optocoupler-IO and Fieldbus interface
Technology: | Inductive transmission principle | |
Sensors: | IS/IE20-30GS | IS/IE42-30GS |
Meas. area: | ||
Steel magn. [FE] | 0.05 ... 4 mm | 0.15 ... 8 mm |
Aluminum [NF] | 0.05 ... 5 (16) mm | 0.1 ... 10 (16) mm |
Stainl. steel aust.[NF] | 0.2 ... 5 (16) mm | 0.5 ... 10 (16) mm |
Non-metals | -- | -- |
Air gap: | 40 mm | 80 mm |
Particularity: | Wall mount enclosure or front panel mounting | Wall mount enclosure or front panel mounting |
Meas. time: | starting from 2 ms | starting from 2 ms |
Applications: | Double Sheet Detection for heat presses, Magnetic belt conveyor, belt conveyors |
Material + Thickness: | see sensors |
Meas. method: | Dual sensor non-contact |
Function principle: | Inductive transmission principle |
Programs: | 255 measurement programs possible |
Paricularities: | Double blank detection, suitable for bowed and vibrating sheets. |
Large sensor gap up to 80 mm (3.15 in.). |